Overview

AMP Standardized systems provide a switch configuration built specifically for the size of the Just Add Power system. Ports are distributed in a controlled way so that systems can be inventoried with a minimal amount of information.

This article covers the standards applied to the switch configuration. Standardized settings on the switch CAN NOT BE MODIFIED. If they are modified, video distribution will break. Other settings that do not affect video distribution can be modified if necessary. Use the information below to determine whether a potential modification will affect video distribution.


Standardized Single Switch Port Connections

In a Standardized AMP system on a single switch, Just Add Power Receivers and Transmitters are assigned specific ports for connection during configuration. AMP allows for any number of Receiver and Transmitter ports to be programmed; this is done in a way that systems that are the same size have the same port connections. For example, every system with 7 Receivers and 4 Transmitters will have devices connected to the exact same ports.

In essence:

  • Receivers go first (Port 1)
  • Transmitters go after Receivers
  • Remaining ports are Data Network ports
  • Network Uplink is in the last RJ-45 port

Reference the table below for port connections for a Single Switch

Device Port # Example
Network Uplink Last RJ-45 port Port connected to the network, or to the control system if there is no larger network
On a 24-port switch, Port 24
Receiver 1 Port 1  
Receiver 2 Port 2  
Receiver 3 Port 3  
... ...  
Receiver X Port X Receivers are at the front of the switch
Transmitter 1 Port X+1
(X = the number of Receivers in the system)
If there are 6 Receivers, Transmitter 1 would be in Port 7
Transmitter 2 Port X+2
(X = the number of Receivers in the system)
If there are 11 Receivers, Transmitter 2 would be in Port 13
Transmitter 3 Port X+3
(X = the number of Receivers in the system)
If there are 7 Receivers, Transmitter 3 would be in Port 10
... ... ...
Transmitter Y Port X+Y
(X = the number of Receivers in the system)
If there are X Receivers, Transmitter Y would be in Port X+Y
Data Network Port Port X+Y+1
(X = the number of Receivers in the system)
(Y = the number of Transmitters in the system)
All ports not assigned to a Just Add Power device are Data Network Ports, configured the same as the Network Uplink port

Standardized Multi-Switch Port Connections

In a Standardized AMP system, Just Add Power Receivers and Transmitters are assigned specific ports for connection during configuration. AMP allows for any number of Receiver and Transmitter ports to be programmed on each switch.

In essence:

  • Receivers go first (Port 1)
  • Transmitters go after Receivers
  • Receivers on Switch 2 start on Port 1 and are numbered immediately after the last Receiver on Switch 1
  • Transmitters on Switch 2 start after the last Receiver on Switch 2 and are numbered immediately after the last Transmitter on Switch 1
  • Repeat Receiver and Transmitter numbering for Switch 3 and beyond
  • Network Uplink is in the last RJ-45 port of Switch 1
  • 10Gb SFP+ ports trunk VLANs 1,100-201 and are assigned to LAGs with 2 SFP+ ports per LAG
  • Remaining ports are Data Network ports

Reference the table below for port connections for Multiple Switches

Device Switch # Port # Example
Network Uplink Switch 1 Last RJ-45 port Port connected to the network, or to the control system if there is no larger network.
Only Switch 1 in a multi-switch system has a Network Uplink port.
Receivers on Switch 1 Same as Single-Switch port connections Receiver 1 = Port 1
Receiver 2 = Port 2
Transmitters on Switch 1 Same as Single-Switch port connections (X = number of Receivers on Switch 1)
Transmitter 1 = Port X+1
Transmitter 2 = Port X+2
Receiver X+1 Switch 2 Port 1 (X = number of Receivers on Switch 1)
If there are 6 Receivers on Switch 1, Receiver 7 would be on Switch 2 Port 1
Receiver X+2 Switch 2 Port 2 (X = number of Receivers on Switch 1)
If there are 23 Receivers on Switch 1, Receiver 25 would be on Switch 2 Port 2
Transmitter Y+1 Switch 2 Port Z+1 (Y = number of Transmitters on Switch 1)
(Z = number of Receivers on Switch 2)
If there are 6 Transmitters on Switch 1 and 20 Receivers on Switch 2; Transmitter 7 would be on Switch 2 Port 21
Transmitter Y+2 Switch 2 Port Z+2 (Y = number of Transmitters on Switch 1)
(Z = number of Receivers on Switch 2)
If there are 10 Transmitters on Switch 1 and 15 Receivers on Switch 2; Transmitter 11 would be on Switch 2 Port 16
Trunk Connections between Switches All Switches SFP+ ports All 10Gb SFP+ ports are trunk ports with membership in VLANs 1,100-201
Data Network Any Switch Remaining Ports If a switch has 10 Receivers and 10 Transmitters, Port 21 and beyond are Data Network ports

Unmodifiable Settings

The settings below are part of Just Add Power's standards and CANNOT be modified:

  • Receiver port settings
  • Transmitter port settings
  • Network Uplink port settings (last RJ-45 port on Switch 1)
  • VLANs 1 & 100-201 settings
  • Switch MOTD Banner
  • Switch Hostname
  • Trunk port VLAN 1,100-201 membership

Modifiable Settings

Disclaimer: Modifying the settings below will PROBABLY not break your system. Only make modifications to an AMP Standardized switch when absolutely necessary.

  • Data Network port settings
  • VLANs 2-99 and VLANs 202 and higher
  • Adding VLANs to trunk ports (as long as VLANs 1,100-201 remain)